This is a conceptual feasibility summary, not a zoning approval, a variance recommendation, an architectural drawing, or a City of Toronto application. Confirm all details with the City and a qualified professional before proceeding.

7 Sample Street, Toronto, ON

Multiplex — Expand the existing home · Prepared August 26, 2026

Larger existing house

Based on recorded property data

The recorded building footprint is 140 m², with 15.0 m of frontage.

Property signals

  • Sixplex-eligible wardThis ward has opted into By-law 654-2025 — up to six residential units may be permitted as-of-right, subject to zoning standards.
  • Wide frontageThis lot is recorded with 15.0 m of frontage.
  • Large lotThis lot is recorded at 570 m².

Chosen configuration

Target units5
Added depth4 m
Rear setback7.5 m
Left side setback1.2 m
Right side setback1.2 m
Height6 m

Property plan

Conceptual property plan showing the parcel boundary. with Existing house, Rear extension. Conceptual feasibility plan — not a survey or architectural drawing.
Conceptual feasibility plan — not a survey or architectural drawing.

What this configuration provides

Footprint128.4 m²
Floor area198.4 m²
Lot coverage30.57%
Storeys

Planning and zoning checks

ItemStatusDetails
Multiplex use permissionWithin recorded standard rulesMulti-unit residential use is a permitted use on this property under the recorded zoning.
Target unit countWithin recorded standard rulesThis property is recorded as eligible for the wider five/six-unit as-of-right tier, and the target unit count is within it.
Building heightWithin recorded standard rulesThe configured building height is within the recorded limit.
StoreysNeeds confirmationStoreys has not been specified in this configuration.
Lot coverageWithin recorded standard rulesThe measured lot coverage is within the recorded limit.
Floor space indexWithin recorded standard rulesThe floor space index is within the recorded limit.
Site-specific exceptionWithin recorded standard rulesNo site-specific zoning exception is recorded for this property.
Constraint layer screeningWithin recorded standard rulesAll required constraint layers (e.g. heritage, tree protection) have been screened for this property.
Rear setbackNeeds confirmationNo authoritative rear setback control is recorded for this property.
Left side setbackNeeds confirmationNo authoritative left side setback control is recorded for this property.
Right side setbackNeeds confirmationNo authoritative right side setback control is recorded for this property.
Building depthNeeds confirmationThe measured building depth cannot be checked — the required front-yard setback for this property is not resolved, and Toronto measures building depth from that required line (Zoning By-law Chapter 800.50(100)), not from the built footprint alone.

Overall: Needs confirmation

Details to confirm

  • Confirm means of egress for every unitOntario Building Code exit/egress requirements (a second exit for units above the ground floor, egress window sizing, travel distance) depend on the final unit layout, which this feasibility check does not design. A designer must confirm means of egress for every proposed unit before permit application.
  • Confirm fire separation between unitsMulti-unit residential buildings require fire-rated separation between dwelling units (and between units and shared/common areas). This pipeline has no source to verify a proposed unit layout against that requirement — a designer must confirm it.
  • Confirm water, sewer, and utility servicing capacityAdditional dwelling units can require upgraded water, sanitary sewer, or electrical service capacity. This pipeline has no source for this property's existing servicing capacity — a designer or the relevant utility must confirm it supports the proposed unit count.
  • Confirm garbage and recycling storageMulti-unit buildings have their own municipal waste storage and collection requirements, distinct from single-family service. This pipeline does not check available storage area against the proposed unit count — a designer must confirm it.
  • Confirm parking requirementsParking requirements for a multiplex depend on the final unit count, unit sizes, and this property's specific zoning parking rules — none of which this pipeline resolves. A designer must confirm parking compliance separately.
  • Confirm accessibility requirementsOntario Building Code accessibility requirements can apply depending on the final unit count and building configuration. This pipeline has no source to determine which requirements apply — a designer must confirm accessibility compliance.

Property envelope

Recorded frontage15 m
Recorded lot depth38 m
Recorded lot area570 m²
Recorded lot typeCorner
Recorded building footprint140 m²
Recorded building height7 m

Things to check

2 layers checked · 0 flagged · 0 unresolved

2 other checked layers returned clear.

Technical zoning

ZoneR (d0.6)
By-lawToronto Zoning By-law 569-2013
Site-specific exceptionNone returned by this zoning screen

Selected approval examples

No approved examples were selected for this configuration.

Sources, search coverage and limitations

Property data as of2026-08-24
Examples considered0
Examples applied0
Constraint screencomplete

No nearby evidence has been applied to this configuration.

  • Parcel geometry: checked
  • Public-data constraint layers: checked

This design was re-evaluated against the property's current recorded data at export time.

Authoritative sources

  • Toronto Zoning By-law 569-2013 (fixture)
  • Synthetic parcel geometry (public sample)
  • Synthetic existing-building record (public sample)
  • Synthetic constraint-layer screen (public sample)
  • Synthetic Major Street screen (public sample)
  • Synthetic sixplex-eligibility screen (public sample)
  • Synthetic technical-zoning record (public sample)

This is a conceptual feasibility summary, not a zoning approval, a variance recommendation, an architectural drawing, or a City of Toronto application. Confirm all details with the City and a qualified professional before proceeding.